Fel! Formatmallen är inte definierad.
AS-215 PC management software
Page 40
Step 7 - Defining Anti Pass-Back zones
Anti Pass-Back zone feature is used when in and out access is controlled.
Because AS- 215 knows whether a user is inside a particular area or out, it can
be intelligent about whether access should be permitted or not. A user must
first exit an area before being allowed to re-enter. This feature can only work
in on-line systems where AS-215 is opened all time.
To add a new Anti Pass-Back zone:
Right click on one of define Anti pass-back zones module and select New.
The Anti pass-back zone dialog box opens.
This dialog box has the following fields:
Field Description
Description
Type in the relevant description for the anti pass-back zone
Access areas
This field defines the protected access area.
Automatic Anti Pass-Back
This field is used to state the anti pass-back time zone
Hard
Denies access and sends alarm to PC
Soft
Grants access but sends an alarm to the PC
Step 8 - Defining Cameras
To add a new camera:
Right click on the Cameras module and click New Camera to open the
Camera dialog box.