Technical Specifications
AC-F/G4x Family Installation and Programming Manual 13
2. Technical Specifications
AC-F43 AC-F44 AC-G43 AC-G44
Input
Voltage
VDC
12 to 24 VDC
VAC
16 to 24 VAC
Maximum Input Current
(12 VDC)
125 mA 160 mA 125 mA 160 mA
Standby Input Current
(12 VDC)
75 mA 95 mA 75 mA 95 mA
Maximum Relay Current
2 A
REX Input
Normally Open (dry contact)
Aux. Input
Normally Open (dry contact)
Max. Proximity Read
Range*
N/A 75 mm
(3.0 in.)
N/A 80 mm
(3.2 in.)
Proximity Modulation
N/A ASK at 125
kHz
N/A ASK at 125
kHz
Proximity Card
Compatibility
N/A 26 Bits EM
cards
N/A 26 Bits EM
cards
LED Indicators
Two 3-colored LED (Mode and Door)
Operating Temp. Range
-30°C to 65°C (-22°F to 150°F)
Operating Humidity
Range
0 to 95% (non-condensing)
Outdoor Usage
Weather resistant, meets IP65, epoxy-potted
Size (H x W x D)
120.9 x 71.1 x 29.7 mm
(4.7 x 2.8 x 1.2 in.)
135.4 x 44.2 x 28.5 mm
(5.3 x 1.7 x 1.1 in.)
Weight
244 g (8.6 oz) 178 g (6.3 oz)
* Measured using a Rosslare proximity card or equivalent. Range also depends
on electrical environment and proximity to metal.